In-Situ Zirconia Oxygen Analyzer Flue Gas O2 Sensor Monitor 4-20mA
Brand Yongan Electronics
Product origin Wuxi, Jiangsu Province
Delivery time 1-10piece(10 -15 days) ;20~100piece(25-30 days)
Supply capacity Annual Production Volume 5,000+
Product Highlights:
1.zirconia oxygen transmitter 4-20mA or RS485 output signal, connectable to PLCs and DCSs.
2.The panel of the zirconia oxygen analyzer directly displays the heating temperature, oxygen concentration, and potential value.
3.The flue gas oxygen analyzer features a high-definition LED digital display that provides clear and intuitive readings, facilitates on-site calibration, and ensures measurement accuracy.
Product details:
The ZOY Series Intelligent Zirconia Oxygen Analyzers enable rapid, accurate, and online monitoring and analysis of the flue gas content generated during the combustion process in equipment such as boilers, kilns, and heating furnaces. This facilitates low-oxygen combustion control, thereby achieving energy conservation objectives and reducing environmental pollution.
Product Specification Sheet:
Model Number | ZOY series |
Prodect Name | Zirconia Oxygen Analyzer |
Detection Range | 0-20%vol,0-25%vol |
Power Supply | 220VAC ±10% 50Hz |
Language Support | English |
Qutput Signal | 4-20mA or RS485 |
Display | LED display |
Flue gas temperature | ZOY-4:0-700℃ ZOY-5:700~1100℃ |
Ambient Temperature | 0–50°C |
Relative Humidity | <90% RH (non-condensing) |
Insertion Depth | 200mm~1500mm (Customizable) |
Product advantages:
1.Comprehensive Certifications: ISO 9001, ISO14001, and ISO45001 ,ensuring full compliance and qualification.
2. Professional Technical Support:Our technical engineers work directly with clients to assist in determining the proper insertion depth for zirconia probes and selecting the appropriate model based on flue gas temperature, as well as to address any product-related concerns clients may have both before and after placing an order.
3. Rapid After-Sales Response: In the event of a quality issue, our technical engineers will immediately diagnose the root cause of the fault and promptly arrange for a replacement shipment or provide a corrective solution.
4. Brand Customization: We offer customization services, including the integration of your company logo and name.
Enterprise Advantages
Company Introduction:

Wuxi Yong'an Electronic Technology Co., Ltd., established in 2011 and headquartered in Wuxi, China, is a high-tech enterprise integrating design, R&D, production, sales, and service. We have been deeply involved in the fields of safety monitoring equipment, industrial instruments, and industrial environment for 15 years. Adhering to the concept that "science and technology are the primary productive forces," we are committed to providing global customers with high-quality products and services, offering one-stop solutions. We serve over 200 international clients in 30 countries. We have a 1000-square-meter production base, a professional team of 100 people, and strictly implement the ISO9001 quality management system. From pre-sales consultation and sample confirmation to after-sales follow-up, we provide dedicated customer service to ensure worry-free procurement.
FAQ;
Q1:How often do need to be calibrated?
Re:There are many interference factors during the use of the zirconia analyzer, such as the aging of the zirconium tube, dust accumulation, corrosion of the electrodes by SO2 and SO3, etc. After running for a period of time, the performance of the instrument will gradually change, bringing errors to the measurement, so the instrument must be calibrated regularly! The calibration cycle is usually 1-3 months, depending on the environment and usage of the instrument.
Calibration standard gas concentration: 5% or 10% oxygen
Q2:How often should the filter be cleaned?
Re:The function of the filter is to prevent impurities in the flue gas from clogging the filter, causing the gas to be unable to enter the sensor in the zirconium tube for measurement.
Regarding the cleaning frequency of the filter, it is first necessary to determine whether the burning substances in the boiler will produce dust impurities. If the burning substances will not produce dust impurities, no cleaning is required. If burning substances will produce dust impurities, the dust concentration needs to be detected. If the concentration is large, the cleaning frequency will be high. If the dust concentration is small, the cleaning frequency will be low. (You can check the filter dust blockage after one month of use. If there is no blockage, you can check it after 2 months. If the blockage is not serious, you can check and clean it once every six months or a year. The specific cleaning frequency depends on the dust blockage in the chimney. Decision).
Q3:What is the standard gas flow rate and pressure during calibration?
Re:During calibration, the standard gas flow rate is 30~100ml/min, The pressure entering the zirconia probe during calibration or testing shall not exceed 80KPa
Q4:To do or not to give instructions during shutdown?
Re:Do not cut off the power of the zirconia analyzer after the furnace is shut down. After the power is turned off, the zirconia probe is in a cooling state. The increase in temperature due to rapid cooling, rapid heating, etc. may cause the zirconium tube to break. Therefore, it is best to avoid unnecessary stop and start operations.